image/svg+xml

General Hospital

Healthcare Environment

Acute Units Analysis for Pseudomonas aeruginosa in water supplies to augmented care units to assist in assessing the risk to patients.
Analysis as described in Guidelines for the Prevention and Control of Infection from Water Systems in Healthcare Facilities Health Protection Surveillance Centre. The Prevention and Control of Infection from Water Systems in Healthcare Facilities Sub-Committee of the HPSC Scientific Advisory Committee, 2015.
Contact Us

Environmental Monitoring

Microbiological monitoring of Operating theatres, Pharmacies, Central Sterilisation Services Departments, Endoscopy Departments, General areas.
Contact and swab analysis of surfaces, settle plate and active air sampling, enumeration and isolation of prominent organisms, trending and statistical analysis.
Contact Us

Aspergillus Monitoring

The analysis of air samples for the presence of Aspergillus in accordance with the National Guidelines for the Prevention of Nosocomial Aspergillosis A Report of the Aspergillosis Subcommittee of the Health Protection Surveillance Centre Scientific Advisory Committee (2018).
Contact Us

General Hospital Potable and Down Services Water Analysis

Total viable counts at 22 and 37°C, Coliforms and Escherichia coli.
Pseudomonas aeruginosa
Legionella Bacteria
Analysis as described in Guidelines for the Prevention and Control of Infection from Water Systems in Healthcare Facilities Health Protection Surveillance Centre. The Prevention and Control of Infection from Water Systems in Healthcare Facilities Sub-Committee of the HPSC Scientific Advisory Committee, 2015.
Contact Us

Closed System Water Analysis

Total viable count, nitrite reducing bacteria, sulphite reding bacteria, Pseudomonas species and chemical analysis of closed system water in the management of water treatment programs - as detailed in BG 29/2021 Pre-Commission Cleaning of Pipework Systems amended 6th edition 2021.
Contact Us

Legionella Analysis

Our laboratories can analyse water samples from cooling towers, evaporative condensers, hot and cold-water systems, spa pools, humidifiers, and fountains/sprinklers in accordance with National Guidelines for the Control of Legionellosis in Ireland, 2009.
Analysis of water samples as part of Legionella control, monitoring or risk assessment policies is carried out as detailed in ISO 11731:2017 “Water Quality-Enumeration of Legionella.
Contact Us
linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram